| Battery voltage | 48 V | Length | 514 mm |
| Width | 292 mm | Height | 665 mm |
| Weight | 34-35 kg | Max charge current | 210 A |
| Battery voltage range | 40-60 V | Max discharge current | 210 A |
| Battery type | lead-acid or lithium-ion | Li-ion strategy | self-adaption to BMS |
| Charging curve | 3 stages / equalization | External temperature sensor | optional |
| Max PV input power | 15 000 W | PV input voltage | 370 V, 125-500 V |
| PV start voltage | 120 V | MPPT range | 150-425 V |
| PV input current | 26+26 A | Max PV Isc | 34+34 A |
| MPPT / strings | 2 MPPT, 2+2 strings | Rated AC power | 10 000 W |
| Max AC power | 12 000 W | Rated AC current | 45.5/43.5 A |
| Max AC current | 50.0/47.8 A | AC passthrough current | 60 A |
| Peak off-grid power | 1.8 times, 10 seconds | AC output | 50/60 Hz, 220/230 V |
| Grid type | single-phase | Power factor | 0.8 leading - 0.8 lagging |
| Current harmonics | THD <3% | Max efficiency | up to 97.90% |
| Euro efficiency | up to 97.00% | MPPT efficiency | up to 99.90% |
| Protection rating | IP65 | Operating temperature | -45 to +60 degrees, possible derating above 45 degrees |
| Cooling | Smart Cooling | Noise | up to 45 dB |
| BMS communication | CAN, RS485 | Display | 5-inch color touch LCD |
| Installation | wall-mounted | Surge protection | DC Type II / AC Type III |
| ARC fault detection | optional | Manufacturer | CHISAGE ESS |
| Levite warranty | 2 years |
Important: derating is possible above 45 degrees. This must be considered during installation, location selection, ventilation planning, load selection and solar power system calculation.
Important: peak off-grid power is a short-term mode and must not be treated as continuous operating load. Solar panels, batteries, protection devices and cables must be selected according to the passport data of the exact equipment revision.
Jup-10G2-LE is a single-phase CHISAGE ESS JUP series hybrid inverter for solar power systems, 48 V battery storage, backup power and off-grid sites. The model is rated at 10 kW and is suitable for private homes, offices, shops, small businesses, server equipment, pumps and sites that require powerful single-phase power.
The inverter combines solar panels, batteries, the utility grid and a backup diesel generator into one energy system. This solution helps use solar energy, store it in batteries, support power during outages and reduce dependence on the external grid.
Jup-10G2-LE supports both grid-connected and off-grid operation. In On-grid mode, the inverter works together with the utility grid, solar panels and batteries, helping power loads, charge the battery and use solar generation more efficiently.
In Off-grid mode, the inverter can support site power without the utility grid by using energy from solar panels, batteries or a diesel generator. EPS output is provided for backup power and On-grid / Off-grid mode switching.
For autonomous operation, up to 20 inverters can be connected in parallel, and different power inverters can also be paralleled. This allows the system to be scaled for larger single-phase loads.
The solar input section is designed for up to 15 000 W PV input power. Two MPPT trackers and a 2+2 string layout allow flexible solar panel connection. MPPT range 150-425 V, start-up voltage 120 V and PV input voltage 370 V with 125-500 V range must be considered when designing solar strings.
The inverter includes protections important for safe operation of a solar energy system: PV input lightning protection, anti-islanding protection, PV string reverse polarity protection, insulation resistance detection, residual current monitoring, output over current protection, output short protection and output over voltage protection.
At Levite, you can choose Jup-10G2-LE for solar panels, 48 V batteries, a single-phase grid, generator backup and real site requirements. The CHISAGE ESS inverter category includes a 2-year store warranty from Levite.